Hirschmann赫斯曼/赫茲曼交換機(jī)
RS20-1600S2S2SDAPHC詢價,上海銳譽為你提供赫斯曼交換機(jī)產(chǎn)品,歡迎咨詢
OpenRail RS20 14xTX-RJ 2xFX(SM-SC / SM-SC)
0-60°C 9,6-60VDC專業(yè)版
Hirschmann Hirschmann
Varenr:RS20-1600S2S2SDAP
Alt鍵。 varenr:943 434-028
產(chǎn)品描述
描述16端口快速以太網(wǎng)交換機(jī),托管,軟件第2層專業(yè),用于DIN導(dǎo)軌存儲轉(zhuǎn)發(fā),無風(fēng)扇設(shè)計
港口類型和數(shù)量共計16個港口; 1.上行鏈路:100BASE-FX,SM-SC; 2.上行鏈路:100BASE-FX,SM-SC; 14 x標(biāo)準(zhǔn)10/100 BASE TX,RJ45
類型RS20-1600S2S2SDAPHH09.0。
訂單號943 434-028
更多接口
電源/信號觸點1個插入式接線端子,6針
V.24接口1 x RJ11插座
USB接口1個USB連接自動配置適配器ACA21-USB
網(wǎng)絡(luò)規(guī)模 - 電纜長度
單模光纖(SM)9 /125μm0 - 32.5 km,1300 nm時16 dB鏈路預(yù)算,A = 0.4 dB / km,3 dB預(yù)留,D = 3.5 ps /(nm x km)
網(wǎng)絡(luò)規(guī)模 - 級聯(lián)性
線 - /星形拓?fù)淙魏?br />環(huán)形結(jié)構(gòu)(HIPER-Ring)數(shù)量開關(guān)50(重新配置時間<0.3秒)
電源要求
工作電壓12/24/48 V DC(9,6-60)V和24 V AC(18-30)V(冗余)
24 V DC 492 mA時的電流消耗
48 V DC 246 mA時的電流消耗
功率輸出Btu(IT)h 40.3
軟件
管理雙軟件映像支持; TFTP; LLDP(802.1AB); LLDP-MED; SSHv1的; SSHv2的; V.24; HTTP; HTTPS;陷阱; SNMP v1 / v2 / v3;遠(yuǎn)程登錄
診斷管理地址沖突檢測;地址重新檢測; MAC通知;信號接觸;設(shè)備狀態(tài)指示; TCPDump的;發(fā)光二極管;系統(tǒng)日志;具有自動禁用功能的端口監(jiān)控;鏈接襟翼檢測;過載檢測;雙工不匹配檢測; RMON(1,2,3,9);端口鏡像1:1;端口鏡像8:1;端口鏡像N:1;系統(tǒng)信息;冷啟動的自我測試;銅纜測試; SFP管理;配置檢查對話框;切換轉(zhuǎn)儲;鏈路速度和雙工監(jiān)控
配置自動配置適配器ACA11有限支持(RS20 / 30/40,MS20 / 30);自動配置撤消(回滾);配置指紋;具有自動配置功能的BOOTP / DHCP客戶端; DHCP服務(wù)器:每個端口; DHCP服務(wù)器:每個VLAN的池; DHCP服務(wù)器:選項43;自動配置適配器ACA21 / 22(USB); HiDiscovery;帶有Option 82的DHCP中繼;命令行界面(CLI); CLI腳本;全功能MIB支持;基于網(wǎng)絡(luò)的管理;上下文相關(guān)幫助
安全基于IP的端口安全;基于MAC的端口安全;基于端口的訪問控制與802.1X;訪客/未驗證的VLAN; RADIUS VLAN分配;每個端口的多客戶端身份驗證; MAC認(rèn)證旁路;受VLAN限制的管理訪問; HTTPS證書管理;限制管理訪問;適當(dāng)使用橫幅; SNMP日志記錄;本地用戶管理;通過RADIUS進(jìn)行遠(yuǎn)程驗證
冗余功能MRP的高級環(huán)配置; HIPER-Ring(經(jīng)理); HIPER-Ring(環(huán)形開關(guān));快速HIPER環(huán);鏈路聚合與LACP;媒體冗余協(xié)議(MRP)(IEC62439-2);冗余網(wǎng)絡(luò)耦合; RSTP 802.1D-2004(IEC62439-1); MSTP(802.1Q); RSTP衛(wèi)兵; RSTP over MRP
工業(yè)簡介EtherNet / IP協(xié)議; PROFINET IO協(xié)議
時間同步SNTP服務(wù)器和客戶端,緩沖RTC
其他PoE(802.3AF);手動電纜交叉; PoE +(802.3AT)
切換禁用學(xué)習(xí)(集線器功能);獨立VLAN學(xué)習(xí);快速老化;靜態(tài)單播/多播地址條目; QoS /端口優(yōu)先級(802.1D / p); TOS / DSCP優(yōu)先排序;每端口出口廣播限制器;流量控制(802.3X); VLAN(802.1Q); GARP VLAN注冊協(xié)議(GVRP);雙VLAN標(biāo)記(QinQ);語音VLAN; GARP組播注冊協(xié)議(GMRP); IGMP Snooping / Querier(v1 / v2 / v3)
環(huán)境條件
工作溫度0oC...60oC
儲存/運輸溫度-40oC...70oC
相對濕度(非冷凝)10%... 95%
MTBF 26。4年(MIL-HDBK-217F)
PCB上的防護(hù)漆沒有
機(jī)械結(jié)構(gòu)
尺寸(寬x高x深)110毫米x 131毫米x 111毫米
安裝DIN導(dǎo)軌
重量600克
防護(hù)等級IP20
機(jī)械穩(wěn)定性
IEC 60068-2-27沖擊15 g,持續(xù)時間11 ms,18次沖擊
IEC 60068-2-6振動1 mm,2 Hz-13.2 Hz,90 min; 0.7克,13.2赫茲-100赫茲,90分鐘; 3.5毫米,3赫茲-9赫茲,10個循環(huán),1個倍頻程/分鐘; 1 g,9 Hz-150 Hz,10個循環(huán),1個倍頻程/分鐘
EMC抗干擾性
EN 61000-4-2靜電放電(ESD)6 kV接觸放電,8 kV空氣放電
EN 61000-4-3電磁場10 V / m(80-1000 MHz)
EN 61000-4-4快速瞬變(突發(fā))2 kV電力線,1 kV數(shù)據(jù)線
EN 61000-4-5浪涌電壓電源線:2 kV(線路/地線),1 kV(線路/線路),1 kV數(shù)據(jù)線
EN 61000-4-6傳導(dǎo)抗擾度3 V(10 kHz-150 kHz),10 V(150 kHz-80 MHz)
EMC發(fā)出免疫力
FCC CFR47第15部分FCC 47 CFR第15部分A類
EN 55022 EN 55022 A類
認(rèn)證
工業(yè)控制設(shè)備的安全cUL 508
危險場所ISA 12.12.01 Class 1 Div。 2
造船N / A
鐵路規(guī)范n / a
變電站N / A
供貨范圍及配件
供貨范圍設(shè)備,接線端子,操作手冊
OpenRail RS20 14xTX-RJ 2xFX(SM-SC/SM-SC)
0-60°C 9,6-60VDC Professional
Hirschmann Hirschmann
Varenr: RS20-1600S2S2SDAP
Alt. varenr: 943 434-028
Product description
Description 16 port Fast-Ethernet-Switch, managed, software Layer 2 Professional, for DIN rail store-and-forward-switching, fanless design
Port type and quantity 16 ports in total; 1. uplink: 100BASE-FX, SM-SC; 2. uplink: 100BASE-FX, SM-SC; 14 x standard 10/100 BASE TX, RJ45
Type RS20-1600S2S2SDAPHH09.0.
Order No. 943 434-028
More Interfaces
Power supply/signaling contact 1 x plug-in terminal block, 6-pin
V.24 interface 1 x RJ11 socket
USB interface 1 x USB to connect the AutoConfiguration Adapter ACA21-USB
Network size - length of cable
Single mode fiber (SM) 9/125 μm 0 - 32.5 km, 16 dB link budget at 1300 nm, A = 0.4 dB/km, 3 dB reserve, D = 3.5 ps/(nm x km)
Network size - cascadibility
Line - / star topology any
Ring structure (HIPER-Ring) quantity switches 50 (reconfiguration time < 0.3 sec.)
Power requirements
Operating voltage 12/24/48 V DC (9,6-60) V and 24 V AC (18-30) V (redundant)
Current consumption at 24 V DC 492 mA
Current consumption at 48 V DC 246 mA
Power output in Btu (IT) h 40.3
Software
Management Dual Software Image Support; TFTP; LLDP (802.1AB); LLDP-MED; SSHv1; SSHv2; V.24; HTTP; HTTPS; Traps; SNMP v1/v2/v3; Telnet
Diagnostics Management Address Conflict Detection; Address Relearn Detection; MAC Notification; Signal Contact; Device Status Indication; TCPDump; LEDs; Syslog; Port Monitoring with Auto-Disable; Link Flap Detection; Overload Detection; Duplex Mismatch Detection; RMON (1,2,3,9); Port Mirroring 1:1; Port Mirroring 8:1; Port Mirroring N:1; System Information; Self-Tests on Cold Start; Copper Cable Test; SFP Management; Configuration Check Dialog; Switch Dump; Link Speed and Duplex Monitoring
Configuration AutoConfiguration Adapter ACA11 Limited Support (RS20/30/40, MS20/30); Automatic Configuration Undo (roll-back); Configuration Fingerprint; BOOTP/DHCP Client with Auto-Configuration; DHCP Server: per Port; DHCP Server: Pools per VLAN; DHCP Server: Option 43; AutoConfiguration Adapter ACA21/22 (USB); HiDiscovery; DHCP Relay with Option 82; Command Line Interface (CLI); CLI Scripting; Full-featured MIB Support; Web-based Management; Context-sensitive Help
Security IP-based Port Security; MAC-based Port Security; Port-based Access Control with 802.1X; Guest/unauthenticated VLAN; RADIUS VLAN Assignment; Multi-Client Authentication per Port; MAC Authentication Bypass; Access to Management restricted by VLAN; HTTPS Certificate Management; Restricted Management Access; Appropriate Use Banner; SNMP Logging; Local User Management; Remote Authentication via RADIUS
Redundancy functions Advanced Ring Configuration for MRP; HIPER-Ring (Manager); HIPER-Ring (Ring Switch); Fast HIPER-Ring; Link Aggregation with LACP; Media Redundancy Protocol (MRP) (IEC62439-2); Redundant Network Coupling; RSTP 802.1D-2004 (IEC62439-1); MSTP (802.1Q); RSTP Guards; RSTP over MRP
Industrial Profiles EtherNet/IP Protocol; PROFINET IO Protocol
Time synchronisation SNTP server and client, Buffered RTC
Miscellaneous PoE (802.3AF); Manual Cable Crossing; PoE+ (802.3AT)
Switching Disable Learning (hub functionality); Independent VLAN Learning; Fast Aging; Static Unicast/Multicast Address Entries; QoS / Port Prioritization (802.1D/p); TOS/DSCP Prioritization; Egress Broadcast Limiter per Port; Flow Control (802.3X); VLAN (802.1Q); GARP VLAN Registration Protocol (GVRP); Double VLAN Tagging (QinQ); Voice VLAN; GARP Multicast Registration Protocol (GMRP); IGMP Snooping/Querier (v1/v2/v3)
Ambient conditions
Operating temperature 0 oC ... 60 oC
Storage/transport temperature -40 oC ... 70 oC
Relative humidity (non-condensing) 10 % ... 95 %
MTBF 26.4 years (MIL-HDBK-217F)
Protective paint on PCB No
Mechanical construction
Dimensions (W x H x D) 110 mm x 131 mm x 111 mm
Mounting DIN Rail
Weight 600 g
Protection class IP20
Mechanical stability
IEC 60068-2-27 shock 15 g, 11 ms duration, 18 shocks
IEC 60068-2-6 vibration 1 mm, 2 Hz-13.2 Hz, 90 min.; 0.7 g, 13.2 Hz-100 Hz, 90 min.; 3.5 mm, 3 Hz-9 Hz, 10 cycles, 1 octave/min.; 1 g, 9 Hz-150 Hz, 10 cycles, 1 octave/min
EMC interference immunity
EN 61000-4-2 electrostatic discharge (ESD) 6 kV contact discharge, 8 kV air discharge
EN 61000-4-3 electromagnetic field 10 V/m (80-1000 MHz)
EN 61000-4-4 fast transients (burst) 2 kV power line, 1 kV data line
EN 61000-4-5 surge voltage power line: 2 kV (line/earth), 1 kV (line/line), 1 kV data line
EN 61000-4-6 conducted immunity 3 V (10 kHz-150 kHz), 10 V (150 kHz-80 MHz)
EMC emitted immunity
FCC CFR47 Part 15 FCC 47 CFR Part 15 Class A
EN 55022 EN 55022 Class A
Approvals
Safety of industrial control equipment cUL 508
Hazardous locations ISA 12.12.01 Class 1 Div. 2
Shipbuilding n/a
Railway norm n/a
Substation n/a
Scope of delivery and accessories
Scope of delivery Device, terminal block, operating manual
- 上一產(chǎn)品:RS30-2402O6O6SDAEHC交換機(jī)
- 下一產(chǎn)品:RS20-2400S2S2SDAEHC軌道交換機(jī)